|  | Reading the alarm codes |  | 
				
					| In order to read the last alarm code memorized in the EEPROM 
					on the PCB: with knob
 • Enter 
					diagnostics mode
 • 
					Irrespective of the type of PCB and configuration, turn the
 programme selector clockwise
					to the 
					tenth position.
 | 
				
					| without knob • Press the 
					Fabrics (1) or Temperature (2) button until LED L10
 lights.
 |  | 
				
					|  | 
					Displaying the alarm   |  | 
				
					| The alarm is displayed by a repeated flashing sequence of 
					the two LEDs (0.4 seconds lit, 0.4 seconds off, with an interval of 2.5 
					seconds between sequences).
 The buzzer (if featured) will sound 
					“bips” in synchronization with the flashing of
 the LEDs.
 • END 
					OF CYCLE LED 
					→ indicates 
					the first digit of the alarm code (family)
 • 
					START/PAUSE → 
					indicates the second digit of the alarm 
					code (number
 within the family)
 These two LEDs are featured on all models (though they are
					configured
 differently), and flash 
					simultaneously.
 | 
				
					| Notes: • The first 
					letter of the alarm code “E” 
					(Error) is not displayed, since this letter is
 common to all alarm codes.
 • The 
					alarm code “families” are shown in hexadecimal; in other 
					words:
 → A
					is represented by 10 flashes
 → B
					is represented by 11 flashes
 → ...
 → F
					is represented by 15 flashes
 • 
					Configuration errors are shown by the flashing of a series 
					of LEDs.
 | 
				
					|  | 
					Examples of alarm displays   |  | 
				
					| Example: Alarm E43 will display the following: • On the 
					display, if featured, E43
 • The 
					sequence of four 
					flashes of the 
					End-of-cycle LED 
					indicates the first number E43;
 • The 
					sequence of three 
					flashes of the 
					Start/Pause 
					LED indicates the second number E43;
 | 
			
			
				
					
					
					
					
					
					
				
				
					| Alarm | Description | Possible malfunction | Action/status of machine | Reset | 
				
					| E00 | No alarm | --- | 
				
					| E11 | Poor water fill before wash cycle | Tap closed or water pressure too low; Drain tube improperly 
					positioned; Water fill solenoid valve is defective; Leaks from water 
					circuit on
 pressure switch; Pressure switch defective; Wiring defective; 
					Main board
 defective.
 | Cycle is paused with door locked | Start | 
				
					| E12 | Difficulty in water fill during drying (maximum time 3 min. water fill in drying during the wash
 load unrolling phase)
 | Tap closed or water pressure too low; solenoid valve; 
					pressure switch water circuit; pressure switches; wiring; main board.
 | Cycle is paused | Start | 
				
					| E13 | Water leaks | Drain tube improperly positioned; Water pressure too low; Water fill solenoid valve is defective; Water circuit on 
					pressure switch is
 leaking/clogged; Pressure switch defective.
 | Cycle is paused with door locked | Start | 
				
					| E21 | Poor draining | Drain tube kinked/clogged/improperly positioned; Drain 
					filter clogged/dirty; Drain pump defective; Pressure switch 
					defective; Wiring
 defective; Main board defective; Electrical current leak 
					between heating
 element and ground.
 | Cycle is paused | Start | 
				
					| E22 | Difficulty in water fill during drying or drying condenser clogged (anti-boiling pressure
 switch closed on “FULL”)
 | Drain hose kinked; filter clogged: drying condenser clogged; 
					drain pump faulty; pressure switches faulty; wiring; main circuit board 
					defective;
 current leakage between heater and ground.
 | Cycle is paused | Start | 
				
					| E23 | Defective triac for drain pump | Drain pump defective; Wiring defective; Main board defective. | Emergency drain procedure - Cycle stops with door unlocked
 | OFF/reset | 
				
					| E24 | Malfunction in sensing circuit on triac for drain pump
 | Main board defective. | Emergency drain procedure - Cycle stops with door unlocked
 | OFF/reset | 
				
					| E31 | Malfunction in pressure switch circuit (frequency of signal from pressure switch out
 of limits)
 | Pressure switch; Wiring; Main board; | Cycle stops with door locked | OFF/reset | 
				
					| E32 | Electronic pressure switch improperly calibrated (level on electronic pressure switch
 differs from 0-66 mm after initial calibration
 drain and when antiboiling pressure switch is
 on “empty”).
 | Tap is closed or water pressure is too low; Solenoid valve;
 Water circuit on pressure switches; pressure switches;
 Wiring; main board;
 | Cycle is paused | Start | 
				
					| E33 | Inconsistency between level on electronic pressure switch and level on antiboiling
 pressure switch 1-2 (fault persists for at least
 60 sec.).
 | Pressure switch defective; Electrical current leak between heating element and ground; 
					Heating
 element; Wiring defective;
 Main board defective.
 Water circuit;
 | Emergency drain procedure - Cycle stops with door unlocked
 | OFF/reset | 
				
					| E34 | Inconsistency between level on electronic pressure switch and level on antiboiling
 pressure switch 2 (fault persists for at least 60
 sec.).
 | Pressure switch defective; Electrical current leak between heating element and ground; 
					Heating
 element; Wiring defective;
 Main board defective.
 Water circuit;
 | Emergency drain procedure - Cycle stops with door unlocked
 | OFF/reset | 
			
			
				
					
					
					
					
					
					
					
					
				
				
					| E35 | Overflow | Water fill solenoid valve is defective; Leaks from water 
					circuit on pressure switch; Pressure switch defective; Wiring defective; 
					Main board
 defective.
 | Cycle stops. Emergency drain procedure. Drain pump continues to
 operate (5 min. on, then 5 min. off, etc.).
 | OFF/reset | 
				
					| E36 | Sensing circuit on antiboiling pressure switch 1 defective
 | Main board defective. Electrical current leak between drying heating element and 
					ground
 | Cycle stops with door locked | OFF/reset | 
				
					| E37 | 1st level sensing circuit faulty | PCB faulty. | Cycle blocked, door locked. | OFF/reset | 
				
					| E38 | Pressure chamber blocked (water level does not vary for at least 30 sec.
 during drum rotation
 | Pressure switch hydraulic circuit; Pressure switches;
 Motor drive belt broken;
 | Heating phase skipped. | --- | 
				
					| E39 | “HV” sensor of anti-overflow level faulty | PCB faulty. | Cycle blocked, door locked. | OFF/reset | 
				
					| E3A | Heating elem. relay sensing faulty | PCB faulty. | Cycle blocked, door locked | OFF/reset | 
				
					| E41 | Door open | Door interlock faulty; wiring faulty; PCB faulty.
 | Cycle paused | Start | 
				
					| E42 | Problems of door closure | Door interlock faulty; wiring faulty; PCB faulty.
 | Cycle paused | Start | 
				
					| E43 | Interlock power supply triac faulty | Door interlock faulty; wiring faulty; PCB faulty.
 | (Safety drain cycle) Cycle blocked | OFF | 
				
					| E44 | Door interlock sensor faulty | PCB faulty. | (Safety drain cycle) Cycle blocked | OFF | 
				
					| E45 | Door interlock sensing circuit triac faulty | PCB faulty | (Safety drain cycle) Cycle blocked | OFF | 
				
					| E51 | Motor power supply triac short-circuited | PCB faulty; current leakage from motor or from wiring. | Cycle blocked, door locked (after 5 attempts)
 | OFF/reset | 
				
					| E52 | No signal from motor tachometric generator | Motor faulty; wiring faulty; PCB faulty | Cycle blocked, door locked (after 5 attempts)
 | OFF/reset | 
				
					| E53 | Motor triac sensing circuit faulty | PCB faulty. | Cycle blocked, door locked | OFF/reset | 
				
					| E54 | Motor relay contacts sticking | PCB faulty; current leakage from motor or from wiring | Cycle blocked, door locked (after 5 attempts)
 | OFF/reset | 
				
					| E57 | Inverter is drawing too much current (>15A) | Motor defective; Wiring defective on inverter for motor, 
					inverter board defective.
 | Cycle stops with door locked (after 5 attempts).
 | OFF/reset | 
				
					| E58 | Motor is drawing too much current (>4.5A) | Motor defective; Wiring defective on inverter for motor, 
					inverter board defective, abnormal motor operation (motor overloaded).
 | Cycle stops with door locked (after 5 attempts).
 | OFF/reset | 
				
					| E59 | No signal from tachometric generator for more than 3 seconds
 | Motor defective; Wiring defective on inverter for motor; Inverter board defective.
 | Cycle stops with door locked (after 5 attempts).
 | OFF/reset | 
				
					| E5A | Overheating on heat dissipater for inverter | Inverter board defective. NTC open (on the inverter board). Overheating caused by continuous operation or ambient 
					conditions (let
 appliance cool down)
 | Cycle stops with door locked (after 5 attempts).
 | OFF/reset | 
				
					| E5B | Input voltage is lower than 175V | Wiring defective, Inverter board defective | Cycle stops with door locked (after 5 attempts).
 | OFF/reset | 
				
					| E5C | Input voltage is too high | Inverter board defective, the mains voltage is too high (measure 
					the mains voltage)
 | Cycle stops with door locked (after 5 attempts).
 | OFF/reset | 
				
					| E5D | Data transfer error between inverter and main board
 | Line interference, Wiring defective, defective main board or 
					inverter board
 | Cycle stops with door locked (after 5 attempts).
 | OFF/reset | 
			
			
				
					
					
					
					
					
					
					
					
				
				
					| E5E | Communication error between inverter and main board
 | Defective wiring between main board and inverter board, Defective inverter board, defective main board
 | Cycle stops | OFF | 
				
					| E5F | Inverter board fails to start the motor | Defective inverter board, Defective wiring, defective main 
					board | Cycle stops with door locked (after 5 attempts).
 | OFF/reset | 
				
					| E61 | Insufficient heating during wash cycle | Defective NTC sensor for wash cycle; Heating element 
					defective; Wiring defective; Main board defective.
 | Heating phase is skipped | Start | 
				
					| E62 | Overheating during wash cycle | Defective NTC sensor for wash cycle; Heating element 
					defective; Wiring defective; Main board defective.
 | Safety drain cycle - Cycle stops with door unlocked
 | OFF/reset | 
				
					| E66 | Relay supplying power to heating element defective
 | Main board defective; Electrical current leak from heating 
					element to ground.
 | Safety drain cycle - Cycle stops with door unlocked
 | OFF/reset | 
				
					| E71 | NTC sensor for wash cycle defective | Defective NTC sensor; Wiring defective; Main board defective.
 | Heating is skipped | Start | 
				
					| E72 | Fault in NTC sensor on drying condenser (voltage out of range = short-circuit, open
 circuit)
 | Drying NTC sensor (condenser) defective; wiring defective; 
					main circuit board defective.
 | Heating is skipped | Start | 
				
					| E73 | Fault in NTC sensor on drying duct (voltage out of range = short-circuit, open circuit)
 | Drying NTC sensor (duct) defective; wiring defective; main 
					circuit board defective.
 | Heating is skipped | Start | 
				
					| E74 | NTC sensor for wash cycle improperly positioned
 | NTC sensor improperly positioned; Defective NTC sensor; 
					Wiring defective; Main board defective.
 | Heating is skipped | Start | 
				
					| E82 | Error in selector reset position | PCB faulty (Wrong configuration data). Selector, wiring | --- | OFF/reset | 
				
					| E83 | Error in reading selector | PCB faulty (Wrong configuration data). Selector, wiring | Cycle cancelled | --- | 
				
					| E84 | Recirculation pump defective (inconsistency between the state of the sensing circuit for the
 recirculation pump and the state of the triac)
 | Recirculation pump; Wiring;
 Main board;
 | Machine drains and cycle stops (with door unlocked)
 | OFF/reset | 
				
					| E85 | Defective sensing circuit on triac for recirculation pump (input voltage on
 microprocessor remains at 0 or 5 V).
 | Main board | Machine drains and cycle stops (with door unlocked)
 | OFF/reset | 
				
					| E91 | Communication error between main board and display board
 | Wiring defective; Control/display board defective Main board defective.
 | Cycle stops | --- | 
				
					| E92 | Inconsistency in communication between main board and display board
 (versions not compatible)
 | Wrong control/display board; Wrong main board (not right for model).
 | Cycle stops | --- | 
				
					| E93 | Configuration error on appliance | Main board defective (Improper programming). | Cycle stops | OFF/reset | 
				
					| E94 | Configuration error on wash cycle | Main board defective (Improper programming). | Cycle stops | OFF/reset | 
				
					| E95 | Communication error between microprocessor and EEPROM
 | Main board defective. | Cycle stops | OFF/reset | 
				
					| E97 | Inconsistency between list of programmes and configuration of cycle
 | Main board defective (Improper programming). | Cycle stops | OFF/reset | 
				
					| E98 | Communication error between microprocessor and clock
 | Display board faulty | The cycle continues | ----------- | 
				
					| EB1 | Frequency of power supplied to appliance out of limits
 | Problems with the power mains (wrong power/interference); 
					Main board defective.
 | Cycle stops | --- | 
			
			
				
					
					
					
					
					
					
					
					
				
				
					| EB2 | Input voltage too high | Problems with the power mains (wrong power/interference); 
					Main board defective.
 | Cycle stops | --- | 
				
					| EB3 | Input voltage too low | Problems with the power mains (wrong power/interference); 
					Main board defective.
 | Cycle stops | --- | 
				
					| EBE | Inconsistency between safety relay and sensing circuit
 | Main board defective, defective wiring | Machine drains and cycle stops (with door unlocked)
 | OFF/reset | 
				
					| EBF | Sensing circuit on safety system defective (input voltage on microprocessor remains at 0
 or 5 V).
 | Main board defective | Machine drains and cycle stops (with door unlocked)
 | OFF/reset | 
				
					| EC1 | Solenoid valve inoperative but flow meter operating
 | Main board defective, Solenoid valve defective | Cycle stops with door locked (after 5 attempts).
 | OFF/reset | 
				
					| EC2 | Signal from turbidity sensor out of limits | Turbidity sensor defective, Main board defective, Wiring 
					defective | ----------------------- | Start/reset | 
				
					| EC3 | Signal from weight sensor out of limits | Weight sensor defective, Main board defective, Wiring 
					defective | --- | Start/reset | 
				
					| EF1 | Drain filter clogged (drain cycle too long)
 | Drain tube clogged/kinked/placed too high; Drain filter dirty/clogged.
 | Warning is displayed at end of cycle (relative LED is lit)
 | --- | 
				
					| EF2 | Too much detergent (too much foam during drain cycles)
 | Too much detergent used; Drain tube clogged/kinked; Drain filter dirty/clogged.
 | Warning is displayed at end of cycle (relative LED is lit)
 | --- | 
				
					| EF3 | “Water Control” system tripped | Water leaks onto base frame; water control system defective. | Machine drains and cycle stops | OFF/reset | 
				
					| EF4 | Water fill pressure too low, no signal from flow meter and solenoid valve is open
 | Tap closed, water pressure too low | --------------------------- | Reset |